TERRA ENERGY
  • Pradžia
  • Apie mus
  • Produktai
    • Šilumos siurbliai Oras-Vanduo
    • Šilumos siurbliai Gruntas-Vanduo
    • Šaldymo centralės
    • Aušinimo mašinos (Čileriai)
    • Kilnojamos šaldymo kameros
    • Nestandartinė skardos gamyba
  • Paslaugos
    • Šaldymo kamerų nuoma
    • Šilumos siurblių gamyba
    • Pramoninių šaldymo įrenginių gamyba
    • Vėdinimo sistemų nestandartinių detalių gamyba
    • Nerūdijančio plieno gaminiai
  • Kontaktai
  • Home
  • About us
  • Products
    • Heat pump air to water
    • Heat pump ground to water
    • Technical information
    • Compressor racks
    • Chiller
    • Movable refrigeration chambers
    • Sheet metal production
  • Services
    • Refrigeration chambers for rent
    • Production of heat pumps
    • Production of industrial refrigeration equipment
    • Production of non-standard parts of ventilation systems
    • Stainless steel non standard products
  • Contacts
  • Pradžia
  • Apie mus
  • Produktai
    • Šilumos siurbliai Oras-Vanduo
    • Šilumos siurbliai Gruntas-Vanduo
    • Šaldymo centralės
    • Aušinimo mašinos (Čileriai)
    • Kilnojamos šaldymo kameros
    • Nestandartinė skardos gamyba
  • Paslaugos
    • Šaldymo kamerų nuoma
    • Šilumos siurblių gamyba
    • Pramoninių šaldymo įrenginių gamyba
    • Vėdinimo sistemų nestandartinių detalių gamyba
    • Nerūdijančio plieno gaminiai
  • Kontaktai
  • Home
  • About us
  • Products
    • Heat pump air to water
    • Heat pump ground to water
    • Technical information
    • Compressor racks
    • Chiller
    • Movable refrigeration chambers
    • Sheet metal production
  • Services
    • Refrigeration chambers for rent
    • Production of heat pumps
    • Production of industrial refrigeration equipment
    • Production of non-standard parts of ventilation systems
    • Stainless steel non standard products
  • Contacts

Heat pump  Ground to Water

Geothermal heat pumps draw heat from deep within the earth, making it a highly reliable heating method that ensures efficient operation in all outdoor weather conditions. The heat pump is easy to integrate into any type of heating or hot water system.
The main advantages of the Ground to water system
  • Quiet operation
  • Quick and easy installation
  • Long lifetime
  • Ensures thermal power regardless of outside temperature
  • Intelligent management
  • Effective heating and cooling
  • Environment friendly
  • Automatically works according to the intended parameters, so the house can be left for a longer period of time
Picture
Heat pump 4,0 kW
  • Heat pump WW3P-4000, WW3P-4000-200-B
  • Heating capacity 4,02 kW 
  • Free Cooling function
  • Electric power 0.89kW 
  • COP 4.52
  • The maximum heating temperature 55°C
  • Unit dimensions (width/depth/height) 622/740/1400 mm
  • Unit dimensions with integrated boiler (width/depth/height) 622/740/1800 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • ​Remote control option
Heat pump 5,0kW
  • Heat pump WW3P-5200, WW3P-5200-200-B
  • Heating capacity 5,25 kW 
  • Free Cooling function
  • Electric power 1,15kW 
  • COP 4.57
  • The maximum heating temperature 55°C​
  • Unit dimensions (width/depth/height) 622/740/1400 mm
  • Unit dimensions with integrated boiler (width/depth/height) 622/740/1800 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • ​Remote control option
Heat pump 6,0kW
  • Heat pump WW3P-6200, WW3P-6200-200-B
  • Heating capacity 6,29 kW 
  • Free Cooling function
  • Electric power 1,37kW 
  • COP 4.59
  • The maximum heating temperature 55°C 
  • Unit dimensions (width/depth/height) 622/740/1400 mm
  • Unit dimensions with integrated boiler (width/depth/height) 622/740/1800 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • ​Remote control option
Heat pump 8,0kW
  • Heat pump WW3P-8200, WW3P-8200-200-B
  • Heating capacity 8,28 kW 
  • Free Cooling function
  • Electric power 1,79kW 
  • COP 4.62
  • The maximum heating temperature 55°C 
  • Unit dimensions (width/depth/height) 622/740/1400 mm
  • Unit dimensions with integrated boiler (width/depth/height) 622/740/1800 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • ​Remote control option
Heat pump 10,0kW
  • Heat pump WW3P-10000, WW3P-10000-200-B
  • Heating capacity 9,95 kW 
  • Free Cooling function
  • Electric power 2,2kW 
  • COP 4.52
  • The maximum heating temperature 55°C 
  • Unit dimensions (width/depth/height) 622/740/1400 mm
  • Unit dimensions with integrated boiler (width/depth/height) 622/740/1800 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • ​Remote control option
Heat pump 11,0kW
  • Heat pump WW3P-11000, WW3P-11000-200-B
  • Heating capacity 10,81 kW 
  • Free Cooling function
  • Electric power 2,4kW 
  • COP 4.5
  • The maximum heating temperature 55°C 
  • Unit dimensions (width/depth/height) 622/740/1400 mm
  • Unit dimensions with integrated boiler (width/depth/height) 622/740/1800 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • ​Remote control option
Heat pump 14,0kW
  • Heat pump WW3P-14000, WW3P-14000-200-B
  • Heating capacity 14,0 kW 
  • Free Cooling function
  • Electric power 3,15kW 
  • COP 4.44
  • The maximum heating temperature 55°C 
  • Unit dimensions (width/depth/height) 622/740/1400 mm
  • Unit dimensions with integrated boiler (width/depth/height) 622/740/1800 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • ​Remote control option
Inverter Heat pump 6,0kW
  • Heat pump Inverter WW3P-6000-I, WW3P-6000-200-BI
  • Heating capacity 6,0 kW 
  • Free Cooling function
  • Electric power 1,31kW 
  • COP 4,59
  • The maximum heating temperature 55°C​
  • Unit dimensions (width/depth/height) 622/740/1400 mm
  • Unit dimensions with integrated boiler (width/depth/height) 622/740/1800 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • ​Remote control option
Inverter Heat pump 8,0kW
  • Heat pump Inverter WW3P-8000-I, WW3P-800-200-BI
  • Heating capacity 8,0 kW 
  • Free Cooling function
  • Electric power 1,80kW 
  • COP 4,44
  • The maximum heating temperature 55°C​
  • Unit dimensions (width/depth/height) 622/740/1400 mm
  • Unit dimensions with integrated boiler (width/depth/height) 622/740/1800 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • ​Remote control option
Inverter Heat pump 10,0kW
  • Heat pump Inverter WW3P-1000-I, WW3P-1000-200-BI
  • Heating capacity 10.0 kW 
  • Free Cooling function
  • Electric power 2.21kW 
  • COP 4.52
  • The maximum heating temperature 55°C 
  • Unit dimensions (width/depth/height) 622/740/1400 mm
  • Unit dimensions with integrated boiler (width/depth/height) 622/740/1800 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • ​Remote control option
Inverter Heat pump 12,0kW
  • Heat pump WW3P-1200, WW3P-12000-200-B
  • Heating capacity 12.0 kW 
  • Free Cooling function
  • Electric power 2.70kW 
  • COP 4.44
  • The maximum heating temperature 55°C 
  • Unit dimensions (width/depth/height) 622/740/1400 mm
  • Unit dimensions with integrated boiler (width/depth/height) 622/740/1800 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • ​Remote control option
Inverter Heat pump 22,0kW
  • Heat pump Inverter WW3P-22000, WW3P-22000-200-BI
  • Heating capacity 22.0 kW 
  • Free Cooling function
  • Electric power 5,10kW 
  • COP 4,31
  • The maximum heating temperature 55°C 
  • Unit dimensions (width/depth/height) 622/740/1400 mm
  • Unit dimensions with integrated boiler (width/depth/height) 622/740/1800 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • ​Remote control option
TECHNICAL DATA SHEET
More info:   ☏​ +370 687 70043   ☏​ +370 686 62692   ✉ info@terraenergy.lt
Vertical Divider

Production

Heat pump production 
Custom made metal products
Chiller production
Industrial heat pumps
Condenser units

PRODUcts

Air to water heat pump
Ground to water heat pump 
Chillers
Mobile refrigerating chambers
Non-standard sheet metal products 
Stainless steel products

Contacts

Mob: +370 687 70043
Mob: +370 686 62692
​
Accounting: +370 616 84248
e-mail: info@terraenergy.lt
Address: Beržuonos g. 19, Vilnius
©2023 Terra Energy, UAB