TERRA ENERGY
  • Pradžia
  • Apie mus
  • Produktai
    • Šilumos siurbliai Oras-Vanduo
    • Šilumos siurbliai Gruntas-Vanduo
    • Šaldymo centralės
    • Aušinimo mašinos (Čileriai)
    • Kilnojamos šaldymo kameros
    • Nestandartinė skardos gamyba
  • Paslaugos
    • Šaldymo kamerų nuoma
    • Šilumos siurblių gamyba
    • Pramoninių šaldymo įrenginių gamyba
    • Vėdinimo sistemų nestandartinių detalių gamyba
    • Nerūdijančio plieno gaminiai
  • Kontaktai
  • Home
  • About us
  • Products
    • Heat pump air to water
    • Heat pump ground to water
    • Technical information
    • Compressor racks
    • Chiller
    • Movable refrigeration chambers
    • Sheet metal production
  • Services
    • Refrigeration chambers for rent
    • Production of heat pumps
    • Production of industrial refrigeration equipment
    • Production of non-standard parts of ventilation systems
    • Stainless steel non standard products
  • Contacts
  • Pradžia
  • Apie mus
  • Produktai
    • Šilumos siurbliai Oras-Vanduo
    • Šilumos siurbliai Gruntas-Vanduo
    • Šaldymo centralės
    • Aušinimo mašinos (Čileriai)
    • Kilnojamos šaldymo kameros
    • Nestandartinė skardos gamyba
  • Paslaugos
    • Šaldymo kamerų nuoma
    • Šilumos siurblių gamyba
    • Pramoninių šaldymo įrenginių gamyba
    • Vėdinimo sistemų nestandartinių detalių gamyba
    • Nerūdijančio plieno gaminiai
  • Kontaktai
  • Home
  • About us
  • Products
    • Heat pump air to water
    • Heat pump ground to water
    • Technical information
    • Compressor racks
    • Chiller
    • Movable refrigeration chambers
    • Sheet metal production
  • Services
    • Refrigeration chambers for rent
    • Production of heat pumps
    • Production of industrial refrigeration equipment
    • Production of non-standard parts of ventilation systems
    • Stainless steel non standard products
  • Contacts

Heat pump air to water

Air to water pumps - produce heat from the ambient air, so the air temperature plays a very important role in this heating system: the smaller the temperature difference between the outdoor air and the indoor air of the building, the more efficiently the system works. Air-water heat pumps are usually built in places where it is not possible to install an earth collector or deep wells, and this heating method is characterized by a good price-quality ratio.

The main advantages of the Air to Water system
  • Simple and quick installation
  • Lower installation costs
  • It doesn't pollute the environment
  • Automatically works according to the set parameters, so the house can be left for a longer period of time
  • The heat pump is easy to integrate into any type of home heating or hot water system.
Picture
Heat pump 5,0kW
  • Heat pump AW1P-5300-I, AW1P-5300-BI
  • Heating capacity 5,3 kW 
  • Cooling function
  • Inverter compressor 
  • Electric power 1,18 kW 
  • COP 4,49
  • The maximum heating temperature 55°C 
  • Indoor unit dimensions (width/depth/height) 500/265/790 mm
  • Dimensions of the indoor unit with integrated boiler (width/depth/height) 622/662/1800 mm
  • Outside unit dimensions (width/depth/height) 890/342/673 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • Remote control option
Heat pump 7,0kW
  • Heat pump AW1P-7100-I, AW1P-7100-BI
  • Heating capacity 7,0 kW 
  • Cooling function
  • Inverter compressor
  • Electric power 1,55 kW 
  • COP 4,52
  • The maximum heating temperature 55°C 
  • Indoor unit dimensions (width/depth/height)
    500/265/790 mm
  • Dimensions of the indoor unit with integrated boiler (width/depth/height) 622/662/1800 mm
  • Outside unit dimensions (width/depth/height) 890/342/673 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • Remote control option
Heat pump 10,0kW
  • Heat pump AW3P-10000-I, AW3P-10000-BI
  • Heating capacity 10,6 kW 
  • Cooling function
  • Inverter compressor 
  • Electric power 2,18 kW 
  • COP 4,86
  • The maximum heating temperature 55°C 
  • Indoor unit dimensions (width/depth/height)
    500/265/790 mm
  • Dimensions of the indoor unit with integrated boiler (width/depth/height) 622/662/1800 mm
  • Outside unit dimensions (width/depth/height) 
    952/415/1333 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • Remote control option
Heat pump 14,0kW
  • Heat pump AW3P-14000-I, AW3P-14000-BI
  • Heating capacity 13,8 kW 
  • Cooling function
  • Inverter compressor 
  • Electric power 2,85 kW 
  • COP 4,84
  • The maximum heating temperature 55°C 
  • Indoor unit dimensions (width/depth/height)
    500/265/790 mm
  • Dimensions of the indoor unit with integrated boiler (width/depth/height) 622/662/1800 mm
  • Outside unit dimensions (width/depth/height) 
    952/415/1333 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • Remote control option
Heat pump 16,0kW
  • Heat pump AW3P-18000-I, AW3P-18000-BI
  • Heating capacity 16,1 kW 
  • Cooling function
  • Inverter compressor 
  • Electric power 3,75 kW 
  • COP 4,29
  • The maximum heating temperature 55°C
  • Indoor unit dimensions (width/depth/height)
    500/265/790 mm
  • Dimensions of the indoor unit with integrated boiler (width/depth/height) 622/662/1800 mm
  • Outside unit dimensions (width/depth/height) 
    952/415/1333 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • Remote control option