TERRA ENERGY
  • Pradžia
  • Apie mus
  • Produktai
    • Šilumos siurbliai Oras-Vanduo
    • Šilumos siurbliai Gruntas-Vanduo
    • Šaldymo centralės
    • Aušinimo mašinos (Čileriai)
    • Kilnojamos šaldymo kameros
    • Nestandartinė skardos gamyba
  • Paslaugos
    • Šaldymo kamerų nuoma
    • Šilumos siurblių gamyba
    • Pramoninių šaldymo įrenginių gamyba
    • Vėdinimo sistemų nestandartinių detalių gamyba
    • Nerūdijančio plieno gaminiai
  • Kontaktai
  • Home
  • About us
  • Products
    • Heat pump air to water
    • Heat pump ground to water
    • Technical information
    • Compressor racks
    • Chiller
    • Movable refrigeration chambers
    • Sheet metal production
  • Services
    • Refrigeration chambers for rent
    • Production of heat pumps
    • Production of industrial refrigeration equipment
    • Production of non-standard parts of ventilation systems
    • Stainless steel non standard products
  • Contacts
  • Pradžia
  • Apie mus
  • Produktai
    • Šilumos siurbliai Oras-Vanduo
    • Šilumos siurbliai Gruntas-Vanduo
    • Šaldymo centralės
    • Aušinimo mašinos (Čileriai)
    • Kilnojamos šaldymo kameros
    • Nestandartinė skardos gamyba
  • Paslaugos
    • Šaldymo kamerų nuoma
    • Šilumos siurblių gamyba
    • Pramoninių šaldymo įrenginių gamyba
    • Vėdinimo sistemų nestandartinių detalių gamyba
    • Nerūdijančio plieno gaminiai
  • Kontaktai
  • Home
  • About us
  • Products
    • Heat pump air to water
    • Heat pump ground to water
    • Technical information
    • Compressor racks
    • Chiller
    • Movable refrigeration chambers
    • Sheet metal production
  • Services
    • Refrigeration chambers for rent
    • Production of heat pumps
    • Production of industrial refrigeration equipment
    • Production of non-standard parts of ventilation systems
    • Stainless steel non standard products
  • Contacts

Heat pump air to water

Air to water pumps - produce heat from the ambient air, so the air temperature plays a very important role in this heating system: the smaller the temperature difference between the outdoor air and the indoor air of the building, the more efficiently the system works. Air-water heat pumps are usually built in places where it is not possible to install an earth collector or deep wells, and this heating method is characterized by a good price-quality ratio.

The main advantages of the Air to Water system
  • Simple and quick installation
  • Lower installation costs
  • It doesn't pollute the environment
  • Automatically works according to the set parameters, so the house can be left for a longer period of time
  • The heat pump is easy to integrate into any type of home heating or hot water system.
Picture
Heat pump 5,0kW
  • Heat pump AW1P-5300-I, AW1P-5300-BI
  • Heating capacity 5,3 kW 
  • Cooling function
  • Inverter compressor 
  • Electric power 1,18 kW 
  • COP 4,49
  • The maximum heating temperature 55°C 
  • Indoor unit dimensions (width/depth/height) 500/265/790 mm
  • Dimensions of the indoor unit with integrated boiler (width/depth/height) 622/662/1800 mm
  • Outside unit dimensions (width/depth/height) 890/342/673 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • Remote control option
Heat pump 7,0kW
  • Heat pump AW1P-7100-I, AW1P-7100-BI
  • Heating capacity 7,0 kW 
  • Cooling function
  • Inverter compressor
  • Electric power 1,55 kW 
  • COP 4,52
  • The maximum heating temperature 55°C 
  • Indoor unit dimensions (width/depth/height)
    500/265/790 mm
  • Dimensions of the indoor unit with integrated boiler (width/depth/height) 622/662/1800 mm
  • Outside unit dimensions (width/depth/height) 890/342/673 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • Remote control option
Heat pump 10,0kW
  • Heat pump AW3P-10000-I, AW3P-10000-BI
  • Heating capacity 10,6 kW 
  • Cooling function
  • Inverter compressor 
  • Electric power 2,18 kW 
  • COP 4,86
  • The maximum heating temperature 55°C 
  • Indoor unit dimensions (width/depth/height)
    500/265/790 mm
  • Dimensions of the indoor unit with integrated boiler (width/depth/height) 622/662/1800 mm
  • Outside unit dimensions (width/depth/height) 
    952/415/1333 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • Remote control option
Heat pump 14,0kW
  • Heat pump AW3P-14000-I, AW3P-14000-BI
  • Heating capacity 13,8 kW 
  • Cooling function
  • Inverter compressor 
  • Electric power 2,85 kW 
  • COP 4,84
  • The maximum heating temperature 55°C 
  • Indoor unit dimensions (width/depth/height)
    500/265/790 mm
  • Dimensions of the indoor unit with integrated boiler (width/depth/height) 622/662/1800 mm
  • Outside unit dimensions (width/depth/height) 
    952/415/1333 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • Remote control option
Heat pump 16,0kW
  • Heat pump AW3P-18000-I, AW3P-18000-BI
  • Heating capacity 16,1 kW 
  • Cooling function
  • Inverter compressor 
  • Electric power 3,75 kW 
  • COP 4,29
  • The maximum heating temperature 55°C
  • Indoor unit dimensions (width/depth/height)
    500/265/790 mm
  • Dimensions of the indoor unit with integrated boiler (width/depth/height) 622/662/1800 mm
  • Outside unit dimensions (width/depth/height) 
    952/415/1333 mm
  • Voltage 3 x 400 V / 50 Hz 
  • Integrated electronic heating system circulation pump, additional el. heater 6.0 kW, 3-way valve for hot water 
  • Acoustic insulation of the housing for quiet operation
  • Reliable SIEMENS controller
  • Priority for hot water preparation
  • Possibility of solar panel management and energy accounting
  • Possibility of accounting for heat supply
  • Remote control option
TECHNICAL DATA SHEET
More info:   ☏​ +370 687 70043   ☏​ +370 686 62692   ✉ info@terraenergy.lt
Vertical Divider

Production

Heat pump production 
Custom made metal products
Chiller production
Industrial heat pumps
Condenser units

PRODUcts

Air to water heat pump
Ground to water heat pump 
Chillers
Mobile refrigerating chambers
Non-standard sheet metal products 
Stainless steel products

Contacts

Mob: +370 687 70043
Mob: +370 686 62692
​
Accounting: +370 616 84248
e-mail: info@terraenergy.lt
Address: Beržuonos g. 19, Vilnius
©2023 Terra Energy, UAB